Low smoke zero halogen flame retardant control cable
An overview, cables:
Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
Second, the production of standard:
Low smoke zero halogen flame retardant control cable to the enterprise standard and reference to GB9330-88 this product is suitable for use in ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
Three control cables, low smoke zero halogen flame retardant technology performance:
The product reference articles IEC227, IEC1034, IEC332 international standard design
Four control cables, low smoke zero halogen flame retardant performance requirements:
1, into A bundle of burning A or B, (coking section height) : 2.5 m or less.
The distance of 2, secondary (without burning) : 50 mm or higher;
3, smoke degree (minimum light transmittance) 60% or higher;
4, HCL content acuities were 0.5 mg/g.
Five, the model name:
model  | The name of the cable  | 
KVV  | Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable  | 
KVVP  | Copper low smoke zero halogen polyolefin insulated and sheathed woven block flame-retardant control cable  | 
KVVP2  | Copper low smoke zero halogen polyolefin insulated and sheathed copper tape screened flame-retardant control cable  | 
KVV22  | Copper low smoke zero halogen polyolefin insulation and sheath steel tape armoured flame-retardant control cable  | 
KVVR  | Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable  | 
KVVRP  | Copper low smoke zero halogen polyolefin insulated and sheathed textile block flame-retardant control cable  | 
KVVP2-22  | Copper low smoke zero halogen polyolefin insulated and sheathed copper belt BingBiGang belt sheathed flame-retardant control cable  | 
KYJY  | Copper core with cross-linked polyethylene insulation polyolefin sheath low smoke zero halogen flame retardant control cable  | 
KYJYP  | Cross-linked polyethylene insulating tape armored low smoke zero halogen (B or C) A kind of flame retardant power cable  | 
KYJYP2  | Communication polyethylene insulated fine steel wire armoured low smoke zero halogen (B or C) A kind of flame retardant power cable  | 
KYJYP3  | Copper core with cross-linked polyethylene insulation polyolefin sheath aluminum-plastic composite belt shielding low smoke zero halogen flame retardant control cable  | 
KYJY23  | Copper core with cross-linked polyethylene insulation polyolefin sheath steel tape armoured low smoke zero halogen flame retardant control cable  | 
KYJYP2/23  | Copper core with cross-linked polyethylene insulation polyolefin sheath copper tape BingBiGang tape armored low smoke zero halogen flame retardant control cable  | 
KYJYP3/23  | Copper core with cross-linked polyethylene insulation polyolefin sheath with lu: su composite BingBiGang armoring low smoke zero halogen flame retardant control cable  | 
"WDZ" : it means low smoke zero halogen flame retardant
Six, cable specifications:
model  | Conductor nominal section (was)  | |||||||
0.5  | 0.75  | 1.0  | 1.5  | 2.5  | 4  | 6  | 10  | |
some  | ||||||||
KVV  | -  | 2 ~ 61  | 2 ~ 14  | 2 ~ 10  | ||||
KVV2  | -  | 4-61  | 4 ~ 14  | 4 ~ 10  | ||||
KVV22   | -  | 7 ~ 61  | 4-61  | 4 ~ 14  | 4 ~ 10  | |||
KVVR  | -  | 4-61  | -  | -  | ||||
KVVRP  | -  | 4-61  | 4 ~ 48  | -  | -  | |||
Note: recommend some series for: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 44, 48 and 52 and 61 core.
Seven, delivery requirements:
1, into a circle of 100 m, a dish should be greater than 100 m;
2, according to the supply and demand both sides agreement to allow any length of delivery, the length of the measurement error of plus or minus 0.5%.

                